PoE Voltage Drop

IEEE 802.3AT/BT STANDARDS LAB
50 meters
ESTIMATED VOLTAGE DROP
4.00V
EXCEEDS 5% TOLERANCE (for 48V)
RESISTANCE
6.67 Ω
ENERGY LOSS
2.40 W
ELECTRICAL PATH SCHEMATIC
PSE56VDC NOMLOAD (PD)52.0V ARRIVALDISTANCE: 50m | AWG 23-4.00V LOSS

Voltage Degradation Profile

Projected loss across distance for standard cable diameters at 0.6A.

Engineering Principles

Copper resistance is the primary driver of voltage drop. While standard PoE accounts for some loss, long-run Type 3 (60W) and Type 4 (90W) systems can fail if Joule Heating isn't calculated.

Vdrop=I×(Rper_meter×L×2)V_{drop} = I \times (R_{per\_meter} \times L \times 2)

Note the multiplication by 2: current must travel the full length of the cable and return, effectively doubling the resistance path compared to simple one-way runs.

THERMAL ADVISORY

"In Saudi high-temp environments, we found that a cable cluster in a 60°C ceiling plenum can see a 15% rise in resistance. This turns a borderline link into a failure. Always use 23 AWG for PoE++ deployments."

Technical Standards & References

REF [IEEE-802.3]
IEEE Standards Association (2022)
IEEE Standard for Ethernet - Section 3: PoE
Defines the hardware specifications for Power over Ethernet including current limits and voltage ranges.
VIEW OFFICIAL SOURCE
REF [ASTM-B3]
ASTM International (2013)
Standard Specification for Soft or Annealed Copper Wire
The baseline for copper resistivity (ρ ≈ 1.724 × 10⁻⁸ Ω·m) used in all gauge resistance calculations.
REF [TIA-568]
TIA/EIA (2017)
Commercial Building Telecommunications Cabling Standard
Specifies use-case limits for Cat5e, Cat6, and Cat6a cabling lengths in enterprise environments.
Mathematical models derived from standard engineering protocols. Not for human safety critical systems without redundant validation.
Partner in Accuracy

"You are our partner in accuracy. If you spot a discrepancy in calculations, a technical typo, or have a field insight to share, don't hesitate to reach out. Your expertise helps us maintain the highest standards of reliability."

Contributors are acknowledged in our technical updates.

PoE Live Circuit Simulator

IEEE 802.3af/at Voltage Drop Analysis

45.18 V
AT DEVICE
PSESWITCH48V+ (POSITIVE)R = 4.70 Ω- (NEGATIVE)PDIP CAMERA45.2VΔV = 2.82V50m (24 AWG)
CABLE LENGTH (m)50m
CURRENT (A)0.60A
CABLE GAUGE24 AWG
VOLTAGE DROP
2.82 V
POWER DELIVERED
27.11 W
POWER LOSS
1.69 W

HEALTHY: Device voltage (45.18V) is above the IEEE 802.3at minimum threshold (42.5V). System is operating within spec.

Electrical Integrity in Network Systems

The Hidden Failure: Voltage Undershoot

Many IP cameras and Wireless Access Points (APs) will "boot up" okay, but fail when their auxiliary systems (like IR Illuminators or high-bandwidth MIMO radios) kick in. This is often due to Voltage Drop.

When the load increases, the drop across the cable resistance increases. If the voltage at the device drops below the minimum threshold defined in the IEEE 802.3 standards, the device will reboot or experience "ghost" connectivity issues.

Thermal Derating

Resistivity increases with temperature. In closed ceiling voids or dense cable trays,ambient temperatures can exceed 50°C.

  • Standard: IEEE 802.3af (PoE), 802.3at (PoE+), 802.3bt (4PPoE).
  • Reference: NFPA 70 National Electrical Code (NEC).

Technical Standards & References

REF [IEEE-802.3bt]
IEEE (2018)
4-pair Power over Ethernet (4PPoE) Standard
The industry standard for high-power (Type 3 and Type 4) PoE delivery.
VIEW OFFICIAL SOURCE
REF [TIA-184-A]
TIA (2017)
Guidelines for Supporting Power Delivery Over Balanced Twisted-Pair Cabling
Best practices for preventing thermal degradation in high-power PoE cable bundles.
VIEW OFFICIAL SOURCE
REF [NEC-725]
NFPA (2023)
National Electrical Code (NEC) Article 725: Remote-Control, Signaling, and Power-Limited Circuits
Safety and installation compliance for power delivery over low-voltage data cabling.
Mathematical models derived from standard engineering protocols. Not for human safety critical systems without redundant validation.

Related Engineering Resources

Partner in Accuracy

"You are our partner in accuracy. If you spot a discrepancy in calculations, a technical typo, or have a field insight to share, don't hesitate to reach out. Your expertise helps us maintain the highest standards of reliability."

Contributors are acknowledged in our technical updates.